Synthes lateral femoral locking plate
WebThe NCB (Non-Contact Bridging) Periprosthetic Femur System is a line of polyaxial locking plates for the treatment of femur fractures, particularly periprosthetic femur fractures. … WebThe Synthes LCP ® Proximal Femur Plate is part of the LCP Periarticular Plating System, which merges locking screw technology with conventional plating techniques. The LCP …
Synthes lateral femoral locking plate
Did you know?
WebMethods: A total of 58 patients with isolated stable intertrochanteric fractures and treated in our hospital during the study period of 2024–2024 by distal locked or unlocked lo Web8 metaphyseal screw hole options. 1.8mm radius of curvature. Designed to avoid interference in the intercondylar notch. Available in lengths up to 415mm. May allow for a …
WebThe new 3.5/4.5 Variable Angle LCP Periprosthetic Proximal Femur Plating System was developed for treatment of Vancouver types A and B fractures. It is offered in stainless … Webto-plate locking. Once both the anterior and posterior locking screws are securely locked to the plate, the central 3.5 mm Conical Screw may be removed and replaced with a 3.5 mm …
http://synthes.vo.llnwd.net/o16/LLNWMB8/INT%20Mobile/Synthes%20International/Product%20Support%20Material/legacy_Synthes_PDF/105385.pdf WebMay 3, 2024 · The locking attachment plate (LAP, Depuy-Synthes, ... solution for such fractures. 17 An additional biomechanical study comparing the use of a LCP/LAP construct to double plating with lateral and anterior ... Asano T, et al. Finite element analysis of double‐plate fixation using reversed locking compression‐distal femoral plates ...
WebDistal Medial Tibial Plate DistalAnterolateral Tibial Plate Proximal Lateral Tibial Plate Distal Lateral Femoral Plate Proximal Humeral Plate TheAxSOS Locking Plate System is …
WebDhs locking plate; 4.5mm t buttress locking plates; 35 mm locking metaphyseal plates; Orif distal clavicle with synthes distal clavicle locking pl... Pediatric hip locking plate; Narrow dynamic compression locking plate; Lateral posterior distal humrus locked plate, so19.lpdhlp, s... Locking raft plate, thickness: 3.5mm, size: 3hole to 13hole ... increased fev1/fvcWeb4 DePuy Synthes Expert Lateral Femoral Nail Surgical Technique AO PRINCIPLES In 1958, the AO formulated four basic principles, which ... H-locking plate 2.7 (X49.690–691) Standard screws Cortex screws B 2.7 mm, self-tapping, … increased flight pricesWeb3.5 mm and 4.5 mm Curved Locking Compression Plate (LCP®) System The DePuy Synthes Trauma Locking Compression Plate (LCP®) System is part of a stainless steel and … increased fire rate fivemWeb(K040336), Synthes Distal Femur LISS (Synthes Anatomic Locked Plating System, K961413), Synthes Locking Condylar Plate System (K000066), Synthes LCP Curved … increased flair signalWebLevel IV, therapeutic study. Background: Nonunion of the distal femur after lateral plating is associated with axial malalignment, chronic pain, loss of ambulatory function, and … increased fitnessWebOlecranon Locking Plate Ⅱ is indicated for Complex extra- and intra-articular olecranon fractures, with Anatomical pre-contoured plate with excellent fit to the olecranon. Tags : Olecranon Hook Locking Plate; Medical product Elbow Set; Olecranon Plates 3.5; 3.5mm Hook Plate; Ulnar Locking Plate ... increased fiber foodsWebDec 1, 2014 · Purpose: To review short-term outcomes of proximal femoral locking compression plate (PF-LCP) fixation for proximal femoral fractures in terms of … increased financial